UPS & Battery Backup Runtime Calculator

UPS & Battery Backup Runtime Calculator

Preparing for a power outage or setting up a solar off-grid system? Calculate the true runtime of your battery bank. Enter your battery capacity, load in Watts, and battery chemistry (Lead-Acid, AGM, LiFePO4) to get a realistic backup time estimate.

1. Battery Specifications:

Discharging a lead-acid battery below 50% permanently damages its internal plates.

2. Power Load & Inverter:

E.g. Router (15W) + Laptop (60W) + TV (75W) = 150 Watts.
Converting DC to AC loses energy as heat.

How to Accurately Calculate Battery Backup Time

Whether you are building a DIY off-grid solar system for your camper van or just buying a backup power station for unexpected blackouts, the math behind battery runtimes can be deceiving. Many beginners simply divide their battery capacity by their appliance's power draw and are disappointed when their power cuts out hours earlier than expected. To get a true estimate, you must account for energy conversion, inverter losses, and the limits of battery chemistry.

Amp-Hours vs. Watt-Hours

A battery rating of "100Ah" does not tell you the full story unless you know the voltage. To calculate the total energy stored, you must convert Amp-hours into Watt-hours (Wh). The formula is: Capacity (Ah) × Voltage (V) = Energy (Wh). A standard 12V 100Ah battery holds 1,200 Watt-hours of energy. Mathematically, it could run a 100-Watt lightbulb for exactly 12 hours.

The Depth of Discharge (DoD) Trap

However, you can almost never use 100% of that 1,200 Wh. The chemistry inside the battery dictates its safe "Depth of Discharge" (DoD). If you ignore this limit, you will permanently destroy the battery.

  • Lead-Acid (Starter Batteries): Car batteries are designed to output massive bursts of power for a few seconds to start an engine. They are not meant to be deeply drained. Draining a lead-acid battery past 50% causes severe sulfation. Therefore, your 100Ah battery only gives you 50Ah of usable power.
  • AGM and GEL: These "Deep Cycle" batteries are built with thicker plates and can safely be discharged to about 60% or 70%.
  • Lithium (LiFePO4): The premium choice for off-grid power. Lithium Iron Phosphate batteries can be safely discharged down to 90% or even 100% without degrading, effectively giving you double the usable energy of a lead-acid battery of the same size.

Inverter Efficiency Matters

Your battery stores DC (Direct Current) power, but your household appliances plug into a wall outlet that uses AC (Alternating Current). To bridge this gap, you use an inverter. The process of stepping up 12V DC to 110V or 220V AC generates heat. Standard inverters have an efficiency rating of 80% to 90%. This means you automatically lose 10-20% of your battery's stored energy just to keep the inverter running. Our calculator factors in all these variables to give you a realistic, safe runtime.